- Microbore means any heating pipe smaller than 15mm. In UK homes it is usually 8mm or 10mm copper, sometimes plastic.
- Narrow pipes block more readily with magnetite sludge, so a single cold radiator on microbore often means a blocked pipe rather than a valve fault.
- A gentle chemical clean, a magnetic filter and correct inhibitor keep most microbore systems healthy.
- Aggressive power flushing does not always clear compacted sludge in microbore, and kinked or damaged sections may need replacing.
- For heat pumps, microbore restricts the flow they need. It can sometimes work in small, well-insulated homes, but larger homes usually need upgrades.
Microbore central heating uses small-diameter pipes, usually 8mm or 10mm, to carry hot water to each radiator instead of standard 15mm pipe. It is neat and quick to install, which is why many homes from the 1970s and 1980s have it. The downside is that the narrow bore blocks more easily with sludge, restricts flow, and can limit low-temperature systems such as heat pumps. Most microbore systems can be kept working with clean water and a filter, and upgrading is only worth it when blockages keep returning or you change your heating system.
What is microbore central heating?
On a conventional system, 15mm or 22mm copper pipes run in loops from the boiler, and each radiator tees off them. On a microbore system, a larger pipe runs from the boiler to one or more manifolds, usually hidden under the floor. From each manifold, a separate pair of thin flow and return pipes runs to each radiator.
Installers liked microbore because the soft, thin copper bends by hand and can be threaded under floors and along skirting with few joints. Homeowners liked it because the pipes are discreet.
Heat Geek, a heating design training body, defines microbore as any pipe smaller than 15mm, including 6mm, 8mm, 10mm and 12mm, and notes that the smaller the pipe, the bigger the restriction (Heat Geek).
How to tell if you have microbore
- The pipes coming up to your radiators look about the thickness of a pencil rather than a finger.
- Both pipes to a radiator often come up close together at one end.
- You may find a manifold, a block with several thin pipes coming off it, under a floorboard near the centre of the house or the airing cupboard.
- Pipes can be bent into gentle curves rather than having elbow fittings.
Common microbore problems
| Problem | Why microbore is prone to it | What you notice |
|---|---|---|
| Sludge blockage | Small bore fills quickly with magnetite debris | One radiator cold or barely warm; others fine |
| Restricted flow | Thin pipe carries less water, so less heat, especially on long runs | Far rooms slow to heat; radiators lukewarm |
| Kinks and crushing | Soft copper is easily flattened under floors or behind furniture | Radiator heats poorly after building work |
| Air locks | Air bubbles block a narrow pipe more easily | Gurgling; radiator will not heat after draining |
| Corroded joints or manifold | Age, and multiple compression joints at the manifold | Weeping joints; pressure loss |
| Poor match for low-temperature heating | Limited flow means less heat at low flow temperatures | Rooms struggle when flow temperature is turned down |
Why sludge hits microbore harder
Every steel radiator corrodes very slowly from the inside, producing black iron oxide called magnetite. It circulates as fine particles and settles wherever water slows down. In a 15mm pipe, a little sludge takes a long time to cause trouble. In an 8mm pipe, it takes much less to narrow the bore significantly.
The giveaway is a single radiator that stays cold even after bleeding and checking the valves, while others on the same system work. Because each radiator has its own pipe from the manifold, a blockage affects that radiator alone. Our guide to one radiator not heating up covers the simpler causes to rule out first, such as a stuck TRV pin or closed lockshield.
Prevention is far cheaper than cure. A magnetic system filter on the return to the boiler catches magnetite before it settles, and correctly dosed inhibitor slows corrosion in the first place. Our explainer on boiler inhibitor covers how it is tested and topped up.
Cleaning a microbore system
Cleaning microbore needs more care than cleaning a standard system.
- Chemical cleaning: a cleaner is added to the system and circulated for a period, loosening sludge, then flushed out. It reaches every pipe and works well for general sludge.
- Power flushing: a pump drives water and chemicals through the system at high flow, radiator by radiator. It can help, but thin pipes limit the flow a machine can push, and heavily compacted sludge in a long microbore run may not move.
- Individual pipe clearing: where one run is blocked, an engineer can isolate it and flush it separately, or replace it if it will not clear.
Whatever method is used, the job should finish with inhibitor dosed to the manufacturer’s level and a filter in place. Our power flush guide explains what a full system clean involves and when it is worth paying for.
Microbore vs 15mm: when to upgrade
Microbore does not need replacing just because it is microbore. Plenty of systems run well for decades. Consider upgrading when:
- the same radiators keep blocking, even after cleaning
- pipes are kinked, flattened or corroded and cannot be repaired neatly
- you are adding radiators or extending, and the existing manifold cannot supply them
- you are fitting larger radiators to run at lower flow temperatures
- you are planning a heat pump or hybrid system
- floors are already up for other work, making the change cheaper and less disruptive
Partial upgrades
You do not always need to replace everything. Common middle-ground options include replacing the main feed to the manifolds with larger pipe, replacing only the longest or worst-performing microbore runs, or replacing the pipework to the rooms that struggle most. An engineer can look at which runs cause the problems before quoting.
Microbore and heat pumps
Heat pumps work best with lower flow temperatures and higher water flow rates than boilers. That makes pipe size more important. Heat Geek explains that microbore restricts the flow a heat pump needs, pushing the flow temperature up and reducing efficiency. It also notes that in well-insulated homes or flats with a heat load of around 6kW or less, microbore can sometimes be made to work without a full repipe.
The options it lists, from cheapest upwards, are better controls and a volumiser, improving insulation to cut the heat needed, adding hydraulic separation, and finally repiping. A proper heat loss survey and pipe assessment decides which applies to your home. Our guide to hybrid heat pump and boiler systems covers one route some homes take.
Caring for microbore with a new boiler
Fitting a new boiler to old microbore is common. A good installer will:
- Check how clean the system water is before quoting.
- Clean the system to the manufacturer’s requirements, often a condition of the boiler guarantee.
- Fit a magnetic filter and dose inhibitor.
- Check that every radiator heats properly before handover.
- Balance the system, as microbore runs to far radiators can be long.
Our article on fitting a new boiler with old radiators covers the wider questions about mixing new and old.
Keep your microbore system flowing
Microbore central heating is not a fault in itself, but it needs clean water to work well. If you have one radiator that keeps going cold, a system that is slow to heat, or plans for a heat pump, get the pipework assessed before spending money elsewhere.
Gasmaster’s engineers clean, repair and upgrade heating systems across Stoke-on-Trent, Staffordshire, Cheshire and Derbyshire. See our central heating services or contact us to book an engineer.
[googlesitekit-end-of-content]
Frequently asked questions
Is microbore heating bad?
No. Microbore heating works well in many homes, especially smaller ones with short pipe runs. Its weaknesses are a higher risk of sludge blockages, restricted flow on long runs and less capacity for low-temperature systems. Keep the water clean with inhibitor and a filter and most microbore systems give years of reliable service.
How do I unblock a microbore pipe to one radiator?
First rule out the simple causes: bleed the radiator, check the lockshield is open and the TRV pin is free. If it is still cold, the run from the manifold is probably blocked. An engineer can isolate and flush that run, or replace it. Avoid forcing water through yourself, as old joints at the manifold can leak.
Can you power flush microbore pipes?
Yes, but results vary. Thin pipes limit how much flow a power flushing machine can push, so heavily compacted sludge in long runs may not clear. Many engineers combine a chemical clean with flushing individual runs. Afterwards, a magnetic filter and inhibitor are needed to stop the problem returning.
How much does it cost to replace microbore with 15mm?
It depends on how many radiators there are, how long the runs are, the floor construction and how much making good is needed afterwards. Replacing pipework under solid floors costs more than under timber floorboards. Get a survey and a written quote that says exactly which runs will be replaced.